Skip to main content
Electrical

Power Points That Spark, Buzz Or Feel Hot

John OwenFounder5 min read

A power point that sparks more than once, buzzes, smells of burning or feels hot has a fault behind the plate, and it stays out of use until a licensed electrician has opened it up. Switch the appliance off, stop using that outlet and turn the circuit off at the switchboard if you can reach it safely. If there is smoke or flame, leave the room and call 000.

These faults are small when they are caught. Left alone, a loose wire keeps heating inside the wall, and that heat is how a small repair becomes a burnt outlet and a damaged cable.

Normal and not normal

A tiny flash inside the socket as a plug goes in, with the appliance already switched on, is current jumping the last gap. It happens once, it is gone in an instant and it leaves no mark.

Everything on this list is a fault:

  • Sparks every time, or sparks while the plug is sitting still
  • A buzz or crackle coming from the plate
  • A plate that feels warmer than the wall around it
  • Brown or black marks on the plate or on the plug pins
  • A smell of burning plastic, or an odd fishy smell, near the outlet
  • A plug that slides out under its own weight

What sits behind the fault

A loose terminal. Each cable is clamped by a small screw behind the plate. Years of heating and cooling can ease that screw, and a loose joint arcs, which is the buzz you hear and the heat you feel.

Worn contacts. The metal contacts that grip the plug pins lose their spring over time. A plug that sits loose makes a poor connection, and a poor connection gets hot.

Too much load. A standard Australian power point is rated at 10 amps. A 2,400 watt heater draws about that on its own, so a heater, a kettle and a powerboard on the same outlet push it past its rating, and the plug is where the heat shows first.

Water. A leak can track through a wall and into an outlet, most often behind a kitchen splashback, on the wall shared with a shower or under a balcony door. Replacing the wet outlet solves half the problem. The other half is the leak, which is why this one belongs with [when a fault sits on the seam between two trades](/blog/when-a-fault-sits-on-the-seam-between-two-trades).

Old or damaged cable. In older buildings the cable insulation can turn brittle and crumble at the terminal. A screw or nail put through a wall does the same damage in a building of any age.

Before the electrician arrives

Turn the circuit off first, then unplug whatever is in the outlet. A plug that is hot or scorched stays where it is until the power is off, and an outlet that is wet does not get touched at all.

Leave the plate on, and do not tape over it and carry on. A photo of the marks, a note of what was plugged in and when it started all help the electrician find the fault sooner.

Anyone who feels a shock from an outlet, even a small one, should treat it as urgent and keep everyone away from it. The line between that and a job that can wait is drawn in [emergency or scheduled, what warrants a callout](/blog/emergency-or-scheduled-what-warrants-a-callout).

If the safety switch trips when the outlet is used, say so. It tells the electrician a lot, and the reasons are in [safety switches and electrical testing](/blog/safety-switches-and-electrical-testing).

The repair

This is licensed electrical work in NSW. The electrician isolates the circuit, proves it dead and takes the plate off, then looks at the terminals and the insulation for heat damage.

Damaged cable is cut back to clean copper and terminated again, and the outlet is replaced. Polarity and earth continuity are tested before the circuit goes back on, and a scorch mark on the wall is filled and painted so nothing shows.

When several outlets on one circuit have the same wear, the whole circuit gets inspected. One burnt outlet can be bad luck, and three in a row points at the cable or the load.

The cause, as well as the outlet

A new outlet on an overloaded wall fails the same way as the old one. If a room relies on powerboards, the real fix is more power points where people use them and a dedicated circuit for a heavy appliance, and the steps are in [adding power points and circuits in older apartments](/blog/adding-power-points-and-circuits-in-older-apartments).

Where water caused the fault, the leak gets fixed first. A dry new outlet on a wall that is still taking water will be wet again after the next shower or the next storm.

In a rental

For a property manager, this is a report that should not wait for the next routine round. One message with the unit, a photo and what the tenant noticed is enough to get it moving.

It seldom arrives alone, either. A dripping tap and a sticking door in the same unit go on the same list and get done by the same team, so the tenant has a safe outlet and the agent has a single report to read.

Our electrical work. Talk to us about a property.

JO

John Owen

Founder

Ample Trade, every trade a property needs held by one accountable team on one contact, across the Eastern Suburbs and the Sydney CBD.

ElectricalPower PointsFaultsSafetyRentals

Tell us about your building.

We will respond with a clear understanding of how we can help.

Get in Touch