Salt Air And Coastal Corrosion In Eastern Suburbs Buildings
A building on the coast in Bondi, Coogee, Maroubra or Clovelly ages on a different clock from the same building a few kilometres inland.
The reason is salt. Wind off the ocean carries fine salt spray, it settles on every surface, and on anything made of metal it keeps working long after the weather has cleared.
How salt does the damage
Salt on its own is not the problem. Salt with moisture is. It draws water out of the air, so a salt deposit on a fitting stays damp longer than a clean surface would, and that damp, salty film is what drives corrosion.
The surfaces that suffer most are the ones rain never rinses. Under eaves, inside balcony soffits, behind balustrade posts and under the lip of a window frame, salt collects and stays, while the exposed face is washed clean every time it rains.
Stainless steel is not one thing
The fitting that most often surprises owners is stainless steel. Stainless comes in different grades, and the common grade used indoors can develop brown staining, often called tea staining, within months of being installed near the coast.
Marine grade stainless, commonly 316, holds up far better in salt air, though it still needs washing down to stay clean. Balustrade fittings, screws, door hardware, hinges and light fittings on the coast should be specified in the right grade from the start, because replacing them later costs more than getting it right the first time.
Metals that should not touch
When two different metals are in contact and salt water bridges them, one of them corrodes more quickly than it would on its own. Stainless screws in aluminium frames, copper pipe against galvanised steel, and steel fixings through zinc flashings are all examples.
On a coastal building this is a common reason fixings fail early, and the answer is either matching the metals or separating them with an insulating washer or sleeve.
Where it shows up on a building
Balustrades and handrails. Fixings at the base of posts sit in standing salt and water. Corrosion there is a safety issue rather than a cosmetic one, and balustrade checks are covered in [stairs, handrails and balustrades](/blog/stairs-handrails-and-balustrades).
Concrete balconies and facades. Salt works into concrete and reaches the reinforcing steel, which rusts, expands and pushes the concrete off. That process is set out in [concrete spalling on balconies and facades](/blog/concrete-spalling-on-balconies-and-facades).
Air conditioning condensers. The outdoor unit's coil is made of thin metal fins with air pulled across them all day. On the coast those fins corrode, and the unit loses capacity well before the end of its expected life. Coastal rated units and coil coatings help, and so does regular rinsing as part of [split system servicing](/blog/split-system-servicing-what-goes-wrong).
External lights and power points. Fittings rated for outdoor use can still corrode at the screws and seals in salt air, and a fitting that lets water in becomes an electrical fault.
Window and door hardware. Rollers, locks and tracks seize, and sliding doors become hard to move.
Roof sheeting and gutters. Manufacturers often set different product choices and warranty conditions for buildings close to breaking surf, so the product on the roof should suit the site.
The maintenance that slows it down
Washing down. Rinsing exposed metal, glass and window frames with fresh water on a regular cycle removes salt before it does damage. It is the most effective thing a coastal building can do, and it costs far less than replacing the fittings it protects.
Paint on a shorter cycle. Coatings on a coastal facade break down sooner, and once they fail the material under them is exposed. Planning for a shorter repaint interval is part of [external painting and when to repaint](/blog/external-painting-and-when-to-repaint).
Inspections that look at the sheltered side. The fixings under the balcony and behind the post matter more than the face that looks fine from the street.
Replacing like with better. When a corroded fitting is replaced, it gets replaced with the coastal grade, not with the same thing that failed.
Why it crosses trades
A corroded balustrade fixing can mean concrete repair, a new post base, waterproofing at the penetration and paint. A failed external light can be an electrical repair, a new fitting and sealing at the wall. A rusted condenser can be a climate job with a plumbing drain and an electrical isolator attached.
On a coastal building those faults tend to arrive together, which is why one team looking at the building from every angle catches the second and third problem while the first is being fixed.
Related Articles
Tell us about your building.
We will respond with a clear understanding of how we can help.
Get in Touch